1. Home
  2. Security Hardening
  3. DISA STIG IIS 6.0 Server V6R16
  4. WA070 IIS6 – A private web server must be located on a separate controlled access subnet.

WA070 IIS6 – A private web server must be located on a separate controlled access subnet.

Details

Private web servers, which host sites serving controlled access data, must be protected from outside threats in addition to insider threats. Insider threat may be accidental or intentional but, in either case, can cause a disruption in service of the web server. To protect the private web server from these threats, it must be located on a separate controlled access subnet and must not be a part of the public DMZ that houses the public web servers. It also cannot be located inside the enclave as part of the local general population LAN.

NOTE: Nessus has not performed this check. Please review the benchmark to ensure target compliance.

Solution

Isolate the private web server from the public DMZ and separate it from the internal general population LAN. This separation must have access control in place to protect the web server from internal threats.

Supportive Information

The following resource is also helpful.

This security hardening control applies to the following category of controls within NIST 800-53: System and Communications Protection.This control applies to the following type of system Windows.

References

Source

Updated on July 16, 2022
Was this article helpful?

Related Articles