Details

It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without an alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected.

Alerts provide organizations with urgent messages.

Solution

Configure the ProxySG to send notifications.

1. Log on to the Web Management Console.
2. Click Maintenance >> Events Logging.
3. Select ‘Severe’.
4. Select the ‘Mail’ tab and enter the email address to receive the email alert.
5. Click ‘Apply’.

Supportive Information

The following resource is also helpful.

This security hardening control applies to the following category of controls within NIST 800-53: Audit and Accountability.This control applies to the following type of system BlueCoat.