1. Home
  2. Security Hardening
  3. DISA Symantec ProxySG Benchmark Alg V1R3
  4. SYMP-AG-000220 – Symantec ProxySG must be configured to send the access logs to the centralized log server continuously.

SYMP-AG-000220 – Symantec ProxySG must be configured to send the access logs to the centralized log server continuously.

Details

Off-loading ensures audit information does not get overwritten if the limited audit storage capacity is reached and also protects the audit record in case the system/component being audited is compromised.

Off-loading is a common process in information systems with limited audit storage capacity. The audit storage on the ALG is used only in a transitory fashion until the system can communicate with the centralized log server designated for storing the audit records, at which point the information is transferred. However, DoD requires that the log be transferred in real time, which indicates that the time from event detection to off-loading is seconds or less.

This does not apply to audit logs generated on behalf of the device itself (management).

Solution

Configure continuous audit log off-loading.

1. Log on to the Web Management Console.
2. Browse to Configuration >> Access Logging >> Logs.
3. Click ‘Upload Schedule’ and select ‘Upload the access log continuously’ option.
4. Click ‘Apply’.

Supportive Information

The following resource is also helpful.

This security hardening control applies to the following category of controls within NIST 800-53: Audit and Accountability.This control applies to the following type of system BlueCoat.

References

Source

Updated on July 16, 2022
Was this article helpful?

Related Articles