Set ‘logging console critical’

Details

Verify logging to device console is enabled and limited to a rational severity level to avoid impacting system performance and management.

Solution

Configure console logging level.
hostname(config)#logging console critical

Supportive Information

The following resource is also helpful.

This security hardening control applies to the following category of controls within NIST 800-53: Audit and Accountability.This control applies to the following type of system Cisco.

References

Source

Updated on July 16, 2022
Was this article helpful?