1. Home
  2. Security Hardening
  3. DISA STIG Cisco Infrastructure L3 Switch V8R29
  4. NET-VLAN-002 – Disabled ports are not kept in an unused VLAN.

NET-VLAN-002 – Disabled ports are not kept in an unused VLAN.

Details

The IAO/NSO will ensure disabled ports are placed in an unused VLAN (do not use VLAN1).

It is possible that a disabled port that is assigned to a user or management VLAN becomes enabled by accident or by an attacker and as a result gains access to that VLAN as a member.

NOTE: This check is derived from the L3 switch guidance, if the scan target is a router the check can be ignored.

NOTE: This check requires manual verification that all ports not in use are assigned to the unused VLAN ID specific to your organization.

NOTE: Nessus has not performed this check. Please review the benchmark to ensure target compliance.

Solution

Assign all disabled ports to an unused VLAN. Do not use VLAN1.

Supportive Information

The following resource is also helpful.

This control applies to the following type of system Cisco.

References

  • CAT|III
  • Rule-ID|SV-3973r2_rule
  • STIG-ID|NET-VLAN-002
  • Vuln-ID|V-3973

Source

Updated on July 16, 2022
Was this article helpful?