1. Home
  2. Security Hardening
  3. DISA STIG VMware ESXi Server 5 STIG V2R1
  4. GEN000240-ESXI5-000058 – The system clock must be synchronized to an authoritative DoD time source.

GEN000240-ESXI5-000058 – The system clock must be synchronized to an authoritative DoD time source.

Details

To assure the accuracy of the system clock, it must be synchronized with an authoritative time source within DoD. Many system functions, including time-based login and activity restrictions, automated reports, system logs, and audit records depend on an accurate system clock. If there is no confidence in the correctness of the system clock, time-based functions may not operate as intended and records may be of diminished value.

Solution

From the vSphere Client: Select the host and click ‘Configuration >> Time Configuration’. Select the properties link and chose ‘Options’. From the General tab start the NTP service and select ‘Start and stop with host’. From the NTP Settings tab click the ‘ Add’ button to add the organization defined, authoritative time source within DoD NTP servers.

Supportive Information

The following resource is also helpful.

This security hardening control applies to the following category of controls within NIST 800-53: Configuration Management.This control applies to the following type of system VMware.

References

Source

Updated on July 16, 2022
Was this article helpful?

Related Articles