Details
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis.
Time stamps generated by the application include date and time. Time is commonly expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.
Solution
Configure the Cisco switch to record time stamps for audit records that can be mapped to UTC or GMT as shown in the example below:
SW1(config)# clock timezone EST -5 0
Supportive Information
The following resource is also helpful.
This security hardening control applies to the following category of controls within NIST 800-53: Audit and Accountability.This control applies to the following type of system Cisco.
References
- 800-53|AU-8b.
- CAT|II
- CCI|CCI-001890
- Rule-ID|SV-220499r604141_rule
- STIG-ID|CISC-ND-001050
- STIG-Legacy|SV-110647
- STIG-Legacy|V-101543
- Vuln-ID|V-220499