Details

Administrators need to be aware of activity that occurs regarding their network device management account. Providing administrators with information regarding the date and time of their last successful logon allows them to determine if any unauthorized activity has occurred. This incorporates all methods of logon, including, but not limited to, SSH, HTTP, HTTPS, and physical connectivity.

NOTE: Nessus has not performed this check. Please review the benchmark to ensure target compliance.

Solution

Configure the BIG-IP appliance to use an approved remote authentication server to notify the administrator of the date and time of the last logon upon successful logon.

Supportive Information

The following resource is also helpful.

This security hardening control applies to the following category of controls within NIST 800-53: Access Control, Configuration Management.This control applies to the following type of system F5.